Sign In | Join Free | My himfr.com
Home > Closed Circuit Fluid Cooler >

Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation

SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD
Contact Now
    Buy cheap Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation from wholesalers
     
    Buy cheap Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation from wholesalers
    • Buy cheap Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation from wholesalers
    • Buy cheap Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation from wholesalers
    • Buy cheap Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation from wholesalers
    • Buy cheap Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation from wholesalers

    Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation

    Ask Lasest Price
    Brand Name : YANYE OR BAOFENG
    Model Number : YCT, YNT, FBN
    Certification : ISO9001 2008
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 299 UNIT / MONTH
    Delivery Time : 60 DAYS
    • Product Details
    • Company Profile

    Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation

    YanYe cooling equipment is widely used in petrochemical, pharmaceutical, steel, automotive, foundry, nuclear power plants, power plants, glass manufacturing, IT factories, food and other fields, and air withered systems, induction furnace, continuous casting equipment, mold, glass melting furnace, air compressors, injection molding machines, welding equipment, painting equipment and other facilities, and to partners in various fields to provide professional technical support and services.

    Advantages of Closed Circuit Cooling Tower (CCCT)

    Personnel Health Protection

    Open cooling water system is subject to water pollution and, as a result, the bacteria of miscellaneous sorts proliferate fast to become a grave threat to human health by dissipating the bacteria containing vapor. A popular disease from open water cooling system is legionnaire that endangers human life by causing pneumonia, which is especially true for people living & working in the buildings with central air conditioners. Closed circuit cooling tower has the largest proportion of cooling water circulating inside enclosed loop, thus is not subject to water pollution. The specially designed louvers not only reduce the limited spray water drift to minimum level, but also effectively stop outside sunlight and particles from entering the tower basin cultivating the growth of bacteria.

    Tube Scaling Prevention

    Most scaling & fouling problems are caused by impurities brought into cooling tubes by process cooling water, which will easily damage heat rejection equipment like melting furnaces, some cases of which involve personnel safety issues. For other equipments like central air conditioner, generators, compressors etc, scaling problems are one of the main reasons for lower operation efficiency and souring maintenance cost. Closed circuit cooling tower eliminates the scaling problems by running de-mineralized process water inside the closed circuit cooling coils so that scaling problem is reduced to the lowest level if not completely eradicated.

    Energy Saving

    Variable frequency control ( VFC) is an option for flexible adjustment of the number and speed of working cooling fans to ambient temperature changes, the data of which can be preset at a certain figure. During winter season, the spray water stops automatically when ambient temperature drops to a certain level using only a set number of operating fans to satisfy the reduced cooling requirements.

    Water Saving

    CCCT system adopts 100% closed circuit circulation for process fluid that saves water from loss in any form. Special baffle is used to reduce unavoidable spray water loss to the lowest point without negative impact on the cooling efficiency. The prominent water saving nature is one of the most important factors deciding the popular use of closed circuit cooling tower.

    Space Saving

    Closed circuit cooling tower is designed to operate within very limited space, accounting for 1/4-1/5 that of open cooling system, saving any form of ground construction. The effective drift eliminator baffle enables closed circuit cooling towers to be used indoors close to production line without wetting the groud.

    Investment Saving

    Closed circuit cooling tower has self-attached water basin and fully enclosed cooling coils for preservation of cooling water that saves any form of ground construction cost. Under open cooling tower system, the large water pool is a necessity to supply all process cooling water, and the related investment will be of no use if the open cooling tower is to be re-installed to a different site.

    User Friendly

    Yanye closed circuit cooling tower can be controlled via remote control panel with clearly defined functional push-buttons and digital display system. Automatic Light & Sound alarm system is installed to remind the operator of extreme working conditions of the cooling system for on time adjustment; VFC technology is available for automatic setting of the cooling tower operation data following ambient changes without human interference. Computer control system is also possible under highly sophisticated cooling system requirements.

    Longer Life Expectancy

    Instead of adopting wooden structure or PVC cooling fills, closed circuit cooling tower is composed of copper or carbon steel cooling coils, zink-aluminum galvanized steel case and stainless steel structures etc that prolongs the trouble-free service life of closed circuit cooling tower.

    Easy Installation and Maintenance

    The installation of closed circuit cooling tower includes merely the connection of piping and electrical system that can be done even by technical workers without training.

    Due to the scaling-free nature of closed circuit cooling tower, a great deal of human efforts for monthly or quarterly maintenance can be saved, which are normally neglected due to the busy production schedule and tend to cause sudden stop with long accummulation of scalings.

    Choosing closed circuit cooling tower comes to be part of our responsibility for protection of life and environment with safe & saving industrial cooling solutions


    FBN-666.8700120000.757.4940-100A0.37DN50DN40DN25DN201350(1600)98018501750350630
    FBN-101011.4700120000.757.4940-100A0.37DN50DN40DN25DN201350(1600)98018501750400720
    FBN-151517.1700*210000*20.75*214.5950-100A0.75DN65DN40DN25DN202000(2250)102020801980520940
    FBN-202022.8700*210000*20.75*214.5950-100A0.75DN65DN40DN25DN202000(2250)1020208019805801050
    FBN-303034.2800*220000*21.5*2298.465-100A1.1DN80DN40DN25DN202500(2850)1250234024408801850
    FBN-404045.6800*220000*21.5*2298.465-100A1.1DN80DN40DN25DN202500(2850)1250234024409602050
    FBN-505057900*224000*22.2*258865-100(I)A2.2DN100DN50DN40DN252500(2850)12503040259010602250
    FBN-606068.4900*224000*22.2*258865-100(I)A2.2DN100DN50DN40DN252500(2850)12503040259011402400
    FBN-707080900*228000*23.0*265880-1003DN100DN50DN40DN252500(2850)15003300280013802870
    FBN-808091.21000*232000*23*265880-1003DN100DN50DN40DN252500(2850)16603810331014403150
    FBN-1001001141000*240000*24*21168.880-100(I)A4DN125DN50DN40DN252500(2850)16603810331018003960
    FBN-125125142.51200*250000*24*21168.880-100(I)A4DN125DN50DN40DN252800(3150)17803860336022504950
    FBN-1501501711200*260000*25.5*21168.880-100(I)A4DN150DN50DN40DN253000(3350)18803910341027005940
    FBN-1751752001300*270000*25.5*213011100-1005.5DN150DN50DN40DN253500(3850)20804270377031506930
    FBN-2002002281500*280000*27.5*213011100-1005.5DN200DN80DN50DN404000(4350)20804270377036007920
    FBN-2502502851600*2100000*27.5*21729.6125-100A7.5DN200DN80DN50DN404500(4850)21604850435043009250
    FBN-3003003421800*2120000*211*21729.6125-100A7.5DN200DN80DN50DN404600(5100)23004950445051509500
    FBN-3503503992000*2140000*211*2232.58.5150-200A11DN250DN80DN50DN405000(5500)250049504450595010750
    FBN-4004004562400*2160000*211*2232.58.5150-200A11DN250DN80DN50DN405300(5800)265049504450685014500

    Quality Clean Energy Closed Circuit Fluid Cooler Easy To Transportation & Installation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)